Determination of trace elements in organic specimens by energy-dispersive x-ray fluorescence using a fundamental parameters method
(Wiley Analytical Science, 1991)
A rapid method for the simultaneous determination of trace elements in milk powder by energy-dispersive x-ray fluorescence has been developed. The measurement system consists of an Si(Li) detector, an x-ray tube coupled ...
A compton peak method for incident angle determination in XRF with annular excitation
(X-Ray Spectrometry, 1992)
Established methods for measuring the incident angle related to XRF when radioisotope annular sources are involved are briefly discussed. As an alternative technique, a direct measurement of the incident angle from the ...